Carrier 48fc 15 ton.

Carrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

Carrier 48FC 5 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 7.5 to 15 Nominal Tons. 48FC 08-16 Series air conditioner pdf manual download. ... Page 75 APPENDIX B — PHYSICAL DATA (cont) 48FC*(M,N)16 — 15 Ton — Physical Data ...Full-scale Carrier quality for a variety of equipment types. DXF/CAD templates are full scale 2D drawings of Carrier products. Drawings are provided for you to assist in the creation, modification, analysis, and optimization of a building design. ... 3-28 Ton Rooftop Units – 48/50TC(Q), 48/50KC(Q), 48/50HC(Q), 48/50LC, EnergyX® models. 48 ... Carrier 6 to 23 Nominal Tons. 48LC WeatherExpert® rooftop units were designed by customers for customers. They are Carrier’s most efficient commercial packaged rooftop ever produced and have some of the industry’s highest IEER’s available. The multi stage cooling compressor logic allows for added comfort, energy savings and humidity control.

The price for a ton of coal varies greatly depending on what kind of coal it is. According to the U.S. Energy Information Administration, the average price for coal in 2012 was $39...View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 7.5 to 15 Nominal Tons. 48FC 08-16 Series air conditioner pdf manual download. ... Page 75 APPENDIX B — PHYSICAL DATA (cont) 48FC*(M,N)16 — 15 Ton — Physical Data ...Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: Single cooling stage models are available from 3 -- 10 ton. Two cooling stage models are available from 7.5 -- 15 ton. SEER up to 13.0. (up to 13.4 with ECM motor) EER's up to 11.1. (up to 11.4 with ECM motor)

04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel Exchanger New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit.

is proprietary to carrier corporation and shall not be used or disclosed to others, in whole or in part, ... - 48fc packaged rooftop gas heating/electric cooling units - 14 seer 3, 4, 5 tons, 15 ieer 6 ton . project: ~untitled1 09/19/2020 prepared by: 12:13pm ... Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat Carrier 48FC 5 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. All 48FC units comply with ASHRAE 90.1-2016 Energy Standard. 4. 48FC units comply with US Energy Policy Act (2005).

12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM14A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...

Do not use R-22 service equipment or components on R-410A refrigerant equipment. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480274-01 Printed in U.S.A. Form 48A-21SI Pg 1 11-21 Replaces: 48A-20SI.

The Carrier rooftop unit (RTU) was designed by customers for customers. With "no-strip" screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton WeatherMaker Carrier rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. Value-added features include:Carrier 48FCFM16A3A6-0A0A0 15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU DCNE, 10 TON STAGE HEAT ROOFTOP GAS/ELECTRIC PACKAGE UNIT, VOLTAGE:460, HERTZ:60, PHASE:3, REFRIGERANT:R-22, CFM:4000, AFUE:80%, EER:9, ... WeatherMaker® 48FC Single …With Weather Series Rooftop Units featuring EcoBlue™ Technology, Carrier is proving that not all rooftops are created equal. EcoBlue™ Technology includes a more compact vane axial fan, which is an industry first for packaged rooftop units, along with a simplified design that helps lower installation and maintenance costs. Turn to the experts today to learn …CE - Carrier EnterpriseNEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Variable speed cooling capacity control on all models. SEER to 20.0. Gas efficiencies up to 81%. Cooling operating range up to 125 °F (52°C) and down to 0°F (-18°C)

Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting (144 pages) Single package rooftop units with systemvu controls version 1.x and puronr (r-410a) refrigerant. Table of Contents General. Manual is suitable for 4 more products: 48GC Series 48GC 05 48GC 04 48GC 06. Brand: Carrier | Category: Air Conditioner | Size: 4.05 MB.Choosing among a broad range of air conditioner brands can be overwhelming. So we've narrowed it down to two brands, YORK® and Carrier, to help you decide. Expert Advice On Improvi...04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel Exchanger10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM12A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 12 = 10 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability Available for Delivery; …48FCFM16A3A5-0A0A0. 48FC = Gas Heat Packaged Rooftop. F = High Heat. M = Single Circuit, Two Stage Cooling Model. 16 = 15 Tons. A = No Smoke or CO 2 sensor. 3 = Direct Drive, Eco Blue, High Static Option. A = Al/Cu - Al/Cu. 5 = 208/230-3-60.8.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM09A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 09 = 8.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel Exchanger

carrier 48fc ton › ... Carrier 48FCFM07A3A6-0A0A0 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 460 VOLT GAS ELECTRIC RTU DCNE. 4.8 (195) · USD 30.8 · In stock. Description. The MRCOOL DIYM218HPC00C07 is a dual zone ceiling cassette mini split that offers 18,000 BTUs of cooling Free Shop now at.

Carrier 48fc 15 Ton, Carrier Commercial Packaged Outdoor Commercial Products Portland, OR, Commercial Cooling Showcase 2019 2019-05-06 ACHR NewsWe have 2 Carrier 48FC Series manuals available for free PDF download: Controls, Start-Up, Operation And Troubleshooting, Installation Instructions. Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting …The Carrier rooftop unit (RTU) was designed by customers for customers. With "no-strip" screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton WeatherMaker Carrier rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. Value-added features include: els are in addition to the 3 to 5 ton models with SEERs up to 17.5 and 12.5 to 23 ton models with IEERs up to 19.1 to provide a full range offering. Ultra high efficiency With IEERs up to 20.8, these new WeatherExpert models help to contrib-ute in LEED credits and help qualify for rebates. The high IEER efficiencies are Three carrier hvac units named finalists in consulting-specifying Carrier 48tced manuals Weathermaker® 48fc single-packaged rooftop units with ecoblue™ technology Manualslib manuals 48tc. Manual and Guide Full List. Home; ... Carrier 14 Seer Air Conditioner - 2 Ton 14 Seer Icp Carrier Grandaire. Check Details. ASHRAE 90.1 compliant. Up to 13.0 SEER, 11.8 IEER, and 11.1 EER. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit. Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Performance Features. ASHRAE 90.1 and Energy Star compliant. Up to 15.6 SEER, 13.0 IEER, and 12.2 EER. Standard cooling operating range up to 125 °F (52°C) and down to 35°F (2°C). Low ambient controllers can bring cooling operation down to -20°F (-29°C) Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 ...48FCEA06A3A5-0A0A0 - 5 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT ... Share. Description. 48FCEA06A2A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models 06 = 5 Tons A = No Smoke or CO 2 sensor 2 ... Brand Carrier; Equipment Type Commercial Packaged …04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel Exchanger

Fig. 1 — 48FC 04-07 Model Number Nomenclature MODEL NUMBER RATED INDOOR AIRFLOW (CFM) 48FC*A/B04 1050 48FC*A/B05 1500 48FC*A/B06 2000 48FC*M/N07 2400 Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 ...

View and Download Carrier 48TC installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit Sizes 04-07 with Puron (R-410A) Refrigerant. 48TC air conditioner pdf manual download. Also for: 48tc-a04, 48tc-a05, 48tc-a06, 48tc-a07.

SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit; Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drainHey Everyone, Working on a Carrier RTU unit model# 48TCEA06A2A5A0A0A0. Customer complaint "thermostat has no power." Found 5 amp breaker tripped on transformer. Whenever R and Y1 closes it pulls 10 amps and trips 5 amp breaker. I removed wires from both contactor solenoids (24v circuit) and still trips. I …Permanently lubricated evaporator-fan motor. Totally enclosed condenser motors with permanently lubricated bearings. Low pressure and high-pressure switch protection. …GAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and time periods set forth herein.20 to 60 Nominal Tons. 48A2 – CV/SAV, Vertical. 48A3 - VAV, Vertical. 48A4 – CV/SAV, Horizontal. 48A5 - VAV, Horizontal. Carrier A Series Rooftop products are pre-wired and charged with refrigerant and tested in both cooling and heating modes at the factory. All models feature an industrial grade cabinet with fully hinged access panels.View and Download Carrier 48HC installation instructions manual online. Single Package Rooftop Gas Heating/Electric Cooling Unit with Puronr (R-410A) Refrigerant Sizes: 04, 05, 06. 48HC air conditioner pdf manual download. Also for: 48hc series, 48hc-a04, 48hc-a05, 48hc-a06.If you’re in the market for a powerful and reliable workhorse, look no further than one ton trucks. These heavy-duty vehicles are designed to handle the toughest jobs with ease, ma...Are you in the market for a half ton towable fifth wheel? If so, you’re in luck. There are plenty of great options out there to choose from. But with so many different models and f...Sizes 04-06 models use single-stage cool-ing capacity control. FEATURES. Standard Base Unit Cabinet. Puron (R-410A) HFC refrigerant • Access panels with easy grip handles. SEER of 14.0 • Innovative, easy starting, no-strip screw feature on unit. Meets or exceeds ASHRAE 90.1 energy efficiency levels access panels.

The Carrier rooftop unit (RTU) was designed by customers for customers. With "no-strip" screw collars, handled access panels, and more the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton WeatherMaker Carrier rooftop unit (RTU) provides optimum comfort and control from a packaged rooftop. Value-added features include:4 ARI* CAPACITIES Cooling Capacities and Efficiencies UNIT 48ES NOMINAL TONS STANDARD CFM NET COOLING CAPACITIES (Btuh) EER** SEER† 024 2 800 23,000 11.0 13.2 030 2--1/2 1000 28,600 11.2 13.5 036 3 1200 34,400 11.0 13.0 042 3--1/2 1400 40,500 11.2 13.2 048 4 1600 46,500 11.2 13.2 060 5 1750 57,000 11.0 13.4 LEGEND6 to 23 Nominal Tons. 48LC WeatherExpert® rooftop units were designed by customers for customers. They are Carrier’s most efficient commercial packaged rooftop ever produced and have some of the industry’s highest IEER’s available. The multi stage cooling compressor logic allows for added comfort, energy savings and humidity control.Instagram:https://instagram. tezlyn figaro net worthbend it over renni rucci lyricsferrandis injurykeurig duo plus troubleshooting 48TC*D/E units for installation in the United States contain use of Carrier's Staged Air Volume (SAV™) 2-speed indoor fan control system. This complies with the U.S. Department of Energy (DOE) efficiency standard of 2018. ... Fig.15 (size 08-16) for base rail details. See Fig. 6 (size 07) for thru-the-base charts.Restore set-points for thermostat and humidistat (Y/N) _____. 2021 Carrier. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 04-53480329-01 Printed in U.S.A. Form 48FC-8-14-01SI Pg CL-2 8-21 Replaces: New. quassan castromarlo hsn A baby carrier offers lots of benefits and should be part of your baby traveling inventory right from the start. Here is a guide to the best. We may be compensated when you click o...Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6+ ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. 48GC units generally comply with ASHRAE 90.1-2016 Energy Standard. Please review size specific data for compliance. 4. kta waimea weekly ad Overview. The Comfort series of air conditioners is designed to give you simple, efficient, affordable cooling. And with impressive SEER ratings they can still make you smile when it comes time to pay your energy bill. California residents please see Proposition 65. 6 TON High Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A2A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat